The MF80 200kW shell-and-tube heat exchanger is engineered for very large volume water heating by transferring thermal energy from boilers, solar systems, or heat pumps to swimming pools, spas, or aquatic systems. Designed for maximum efficiency, it is available in titanium (for salt/chlorine pools) or 316L stainless steel (for freshwater).
✅ Technical Specifications
Parameter | Specification |
---|---|
Model | MF80-200 |
Nominal Heating Capacity | 200 kW |
Primary Fluid | Hot water (boiler, heat pump, solar, geothermal) |
Secondary Fluid | Pool or spa water |
Primary Inlet Temperature | Up to 90°C |
Secondary Outlet Temp. | Max 45°C |
Primary Flow Rate | ~8.5–10.0 m³/h |
Secondary Flow Rate | ~35–40 m³/h |
Material Options | Titanium (salt/chlorine) or 316L Stainless Steel |
Heat Exchange Surface Area | Approx. 3.0–3.5 m² |
Max Pressure – Primary | 10 bar |
Max Pressure – Secondary | 3 bar |
Connection Size – Primary | DN50 or 2" BSP / flanged option |
Connection Size – Secondary | DN65–DN80 or 2.5"–3" BSP / flanged option |
Installation Position | Horizontal recommended; vertical optional |
Net Weight | ~25–35 kg |
Certifications | CE Marked, PED Compliant, ISO 9001 |
🔧 Key Features
Extremely high 200kW heat output – for pools over 400–500 m³
Titanium shell option – for aggressive water with chlorine/salt
Compact and rugged design
Very high thermal transfer efficiency
Low maintenance with no moving parts
Easy to integrate into existing mechanical systems
Threaded or flanged connections available
📦 Applications
Olympic swimming pools
Commercial and hotel pools
Spa complexes
Thermal and wellness centers
Aquatic parks
Industrial or geothermal water heating systems
🛠️ Installation Guidelines
Install horizontally for optimal flow distribution
Use isolation valves and flow sensors for system protection
Ensure adequate flow on both primary and secondary sides
Choose titanium version for salt-chlorinated pools
Insulate all external piping to minimize heat loss